| 参数及测量范围(mg/L) | DR6000 | DR3900 | DR1900 | DR900 | 试剂货号 | 备注 | |
| 甲草胺 | - | ● | ● | ● | 28130-00 | 免疫管法 | |
| 铝 | 0.008-0.800 | ● | ● | ● | ● | 2242000-CN | |
| 0.002-0.250 | ● | ● | ● | 2603700-CN | |||
| 0.02-0.50 | ● | ● | ● | TNT848 | |||
| 砷 | 0-0.200 | ● | ● | ● | 1457142-CN;134-49;14580-42;1456842-CN;14469-49;14476-24;14569-42;79501-CN. | 需另配: 棉球(2572-01); 砷蒸馏装置(22654-00); 通用蒸馏装置(22653-00); 蒸馏加热装置 (22744-02) ; 25mL方形比色池(26126-02) | |
| 阿特津,莠去津(除草剂) | - | ● | ● | ● | 27627-00 | 免疫管法 | |
| 钡 | 2-100 | ● | ● | ● | 1206499-CN | ||
| 苯并三唑、 甲苯并三唑 | 1.0-16.0(苯并三唑)、1.0-20.0(甲苯并三唑) | ● | ● | ● | ● | 2141299-CN | 需另配:紫外灯(20828- 02); 带25mL刻度的样品池17042-00(比色计不需要) |
| 硼 | 0.2-14.0 | ● | ● | ● | 1417099-CN | ||
| 溴 | 0.05-4.50 | ● | ● | ● | ● | 2105669-CN | |
| 一氯胺 | 0.1-10.0(Cl2) | ● | ● | ● | 2805145-CN | DR6000/DR3900/DR1900需配 | |
| 0.04-4.50(Cl2) | ● | ● | ● | ● | 2802246-CN | 多光程比色池(48643-02),比色计不需配 | |
| 氯化物 | 0.1-25.0 | ● | ● | ● | 2319800-CN | ||
| 二氧化氯 | 0.04-5.00 | ● | ● | ● | ● | 2770900-CN | |
| 1-50 (直读) | ● | ● | ● | ● | - | ||
| 5-1000(直读) | ● | ● | ● | - | |||
| 0.01-1.00 | ● | ● | ● | 2242300-CN | |||
| 游离余氯 | 0.02-2.00 | ● | ● | ● | ● | 2105569-CN | |
| 0.02-2.00 | ● | ● | 2556900-CN | 需另配流通池,订货信息详见相 关产品的订购指南DR6000/DR3900/DR1900需配 | |||
| 0.04-4.50 | ● | ● | ● | ● | 2802299-CN | 多光程比色池(48643-02),比色计不需配 | |
| 0.05-2.00 | ● | ● | ● | TNT866-CN | 靛酚法 | ||
| 0.1-10.0 | ● | ● | ● | ● | 1407099-CN | DR6000/DR3900/DR1900需配多光程比色池(48643-02),比色计不需配 | |
| 0.09-5.00 | ● | ● | ● | ● | 2105545-CN | ||
| 总余氯 | 0.02-2.00 | ● | ● | ● | ● | 2105669-CN | |
| 0.02-2.00 | ● | ● | ● | 2557000-CN | 需另配流通池,订货信息详见相 关产品的订购指南 | ||
| 0.1-10.0 | ● | ● | ● | ● | 1406499-CN | DR6000/DR3900/DR1900需配多光程比色池(48643-02),比色计不需配 | |
| 2-500μg/L | ● | ● | ● | 2563000-CN | 需另配流通池,订货信息详见相 关产品的订购指南 | ||
| 0.09-5.00 | ● | ● | ● | ● | 2105645-CN | ||
| 余氯&总氯 | 0.05-2.00 | ● | ● | ● | TNT867 | ||
| 六价铬 | 0.010-0.700 | ● | ● | ● | ● | 1271099-CN | |
| 总铬 | 0.01-0.70 | ● | ● | ● | ● | 2242500-CN | 需另配25mL样品瓶(24019-06), DR900无需配。 |
| 六价铬&总铬 | 0.03-1.00 | ● | ● | ● | TNT854 | ||
| 钴 | 0.01-2.00 | ● | ● | ● | 2651600-CN | ||
| 色度 | 3-200度 | ● | ● | — | 需另配5cm光程的矩形比色池(26292- 50);水样浑浊时需经0.45μm的滤膜过 滤 | ||
| 15-500度 | ● | ● | ● | ● | — | 水样浑浊时需经0.45μm的滤膜过滤 | |
| 铜 | 0.04-5.00 | ● | ● | ● | ● | 2105869-CN | |
| 0.1-8.0 | ● | ● | ● | TNT860 | 若需检测总铜,需另购样品制备试剂TNT890;DRB200消解器需要配备20mm及13mm的消解孔 | ||
| 1-210μg/L | ● | ● | ● | ● | 2603300-CN | ||
| 氰化物 | 0.002-0.240 | ● | ● | ● | ● | 2430200-CN | 若要蒸馏,需另配: 通用蒸馏装置(22653-00); 氰化物蒸馏装置(22658-00); 加热装置(22744-02); 实验室自升式平台(22743-00) |
| 氰尿酸 | 5-50mg/L | ● | ● | ● | 246066-CN | ||
| 7-55mg/L | ● | ||||||
| 氟化物 | 0.02-2.00 | ● | ● | ● | ● | 44449-CN | |
| 甲醛 | 3-500μg/L | ● | ● | ● | 2257700-CN | ||
| 硬度 | 0.05-4.00 CaCO3 | ● | ● | ● | ● | 2319900-CN | |
| 总硬度 | 8-1000μg/L CaCO3 | ● | ● | ● | 2603100-CN | 需配1英寸方形带盖塑料样品池 24102-12 | |
| 4-1000μg/L CaCO3 | ● | ● | ● | 2589549-CN + 2589636-CN | 需另配流通池,订货信息详见相关产品的订 购指南 | ||
| 联氨 | 4-600μg/L | ● | ● | ● | ● | 179032-CN | |
| 碘 | 0.07-7.00 | ● | ● | ● | 2105669-CN | ||
| 铁 | 0.009-1.400 | ● | ● | ● | ● | 230166-CN | |
| 0.009-1.400 | ● | ● | ● | 230149-CN | 需另配流通池,订货信息详见相关产品的订 购指南 | ||
| 0.2-6.0 | ● | ● | ● | TNT858 | 若需测总铁,需另购样品制备试剂 TNT890,DRB200消解器需要配备 20mm及13mm的消解孔; 若样品色度及浊度较高,可另购空白试剂 TNT919 | ||
| 0.3-100 μg/L | ● | 230149-CN | 需配10cm光程比色池[2629201],适配 器[LZV887]和滴瓶[2937606] | ||||
| 亚铁 | 0.02-3.00 | ● | ● | ● | ● | 103769-CN | |
| 总铁 | 0.01-1.80 | ● | ● | ● | ● | 2544800-CN | |
| 0.02-3.00 | ● | ● | ● | ● | 2105769-CN | ||
| 0.012-1.800 | ● | ● | ● | ● | 2608799-CN | ||
| 铅 | 5-150μg/L | ● | ● | ● | 2375000-CN | ||
| 3-300μg/L | ● | ● | ● | 1420299-CN | 需自行购买氯仿 | ||
| 1261699-CN | |||||||
| 245053-CN | |||||||
| 245026-CN | |||||||
| 锰 | 0.1-20.0 | ● | ● | ● | ● | 2430000-CN | |
| 0.006-0.700 | ● | ● | ● | ● | 2651700-CN | ||
| 汞 | 0.1-2.5μg/L | ● | ● | ● | 2658300-CN | 需配冷蒸汽汞装置(26744-00)真空泵(28248-02)及温度计(26357-00) | |
| 钼酸盐 | 0.2-40.0 Mo | ● | ● | ● | ● | 2604100-CN | |
| 0.02-3.00 Mo | ● | ● | ● | ● | 2449400-CN | ||
| 镍 | 0.02-1.80 | ● | ● | ● | 212368 | 需自行购买氯仿,需另配25mL的 带盖比色池26126-02 | |
| 212468 | |||||||
| 0.006-1.000 | ● | ● | ● | ● | 2651600-CN 2242600-CN(DR890) | ||
| 0.1-6.0 | ● | ● | ● | 若需检测总镍,需另购样品制备试剂TNT890;DRB200消解器需配备20mm及13mm的消解孔 | |||
| 硝酸盐 | 0.3-30 NO3-N | ● | ● | ● | ● | 2106169-CN | |
| 0.1-10.0 NO3-N 0-5.0 NO3-N(DR900) | ● | ● | ● | ● | 2106169-CN | ||
| 0.1-10.0 NO3-N(UV直读法) | ● | ||||||
| 0.01-0.50 NO3-N | ● | ● | ● | ● | 2429800-CN | ||
| 0.2-30.0 NO3-N | ● | ● | ● | ● | 2605345-CN | ||
| 0.23-13.5 NO3-N | ● | ● | ● | TNT835 | |||
| 5-35 NO3-N | ● | ● | ● | TNT836 | |||
| 总碱度 | 25-400 CaCO3 | ● | ● | ● | TNT870-CN | ||
| 亚硝酸盐 | 0.002-0.300mg/L NO2-N | ● | ● | ● | 2107169-CN | ||
| 0.005-0.35mg/LNO2-N | ● | 2107169-CN | |||||
| 2-150mg/L NO2-N | ● | 2107569-CN | |||||
| 2-250mg/L NO2-N | ● | ● | ● | 2107569-CN | |||
| 0.003-0.500mg/L NO2-N | ● | ● | ● | ● | 2608345-CN | ||
| 0.015-0.600mg/L NO2-N | ● | ● | ● | TNT839 | |||
| 0.6-6.0mg/L NO2-N | ● | ● | ● | TNT840-CN | |||
| 氨氮 | 0.02-2.50mg/L NH3-N | ● | ● | ● | ●(无纳氏 法) | 2458200-CN(纳氏法)2604545-CN(水杨酸法) | 水样浑浊时,纳氏法需蒸馏预处理,配置通用型蒸馏装置(22653-00)及加热装置(22744-02) |
| 0.01-0.50mg/L NH3-N | ● | ● | ● | ● | 2668000-CN | ||
| 0.4-50.0mg/L NH3-N | ● | ● | ● | ● | 2606945-CN | 干扰严重时需要蒸馏,通用型蒸 馏装置(22653-00)及加热装置(22744-02) | |
| 2-47mg/L NH3-N | ● | ● | ● | TNT832 | |||
| 0.015-2.00mg/L NH3-N | ● | ● | ● | TNT830-CN | |||
| 1-12mg/L NH3-N | ● | ● | ● | TNT831 | |||
| 游离氨 | 0.0-0.50 mg/L NH3-N | ● | ● | ● | ● | 28797-00 | DR6000/DR3900/DR1900需配多光程比色池(48643-02),比色计不需配 |
| 总氮 | 5-40mg/L N | ● | ● | ● | TNT827 | 需要DRB200配备直径20mm及13mm的消解孔 | |
| 2-150mg/L N 10-150mg/L N (DR900) | ● | ● | ● | ● | 2714100-CN | 需要DRB200配备16mm的消解孔 | |
| 0.5-25.0mg/L N | ● | ● | ● | ● | 2672245-CN | 需要DRB200配备16mm的消解孔 | |
| 1-16mg/L N | ● | ● | ● | TNT826 | 需要DRB200配备20mm及13mm 的消解孔 | ||
| 20-100mg/L N | ● | ● | ● | TNT828 | 需要DRB200配备直径20mm及 13mm的消解孔 | ||
| 总无机氮 | 0.2-25.0mg/L N | ● | ● | ● | ● | 2604945-CN + 2604545-CN | |
| 总凯氏氮 | 1-150mg/L | ● | ● | ● | ● | 24953-00 | 需配总凯氏氮消解装(23130-21) |
| 0-16mg/L(亚硝氮可忽略时) | ● | ● | ● | TNT880 | DRB200消解器需配备20mm及13mm的消解孔 | ||
| 有机物,紫外吸收 | N/A | ● | - | 水样需要0.45微米膜过滤 | |||
| 总有机碳(TOC) | 100-700mg/L C | ● | ● | ● | 2760445-CN | ||
| 20-700mg/L C | ● | ||||||
| 0.3-20.0mg/L C | ● | ● | ● | ● | 2760345-CN | ||
| 15-150mg/L C | ● | ● | ● | ● | 2815945-CN | ||
| 30 - 300 mg/L C | ● | ● | ● | TNT811 | 需另配DRB200消解器带13mm消解孔 | ||
| 1.5 - 30 mg/L C | ● | ● | ● | TNT810 | 需另配DRB200消解器带13mm消解孔 | ||
| 化学需氧量(CODCr) | 3-150mg/L COD | ● | ● | ● | ● | 2125825-CN | 需另配DRB200消解器 |
| 20-1500mg/L COD | ● | ● | ● | ● | 2125925-CN | ||
| 200-15000mg/L COD | ● | ● | ● | ● | 2415925-CN | ||
| 0.7-40mg/L COD | ● | ● | ● | 2415825-CN | |||
| 1-60mg/L COD | ● | ● | ● | TNT820-CN | |||
| 3-150mg/L COD | ● | ● | ● | TNT821 | |||
| 20-1500mg/L COD | ● | ● | ● | TNT822 | |||
| 250-15000mg/L COD | ● | ● | ● | TNT823 | |||
| 25-1000mg/L COD | ● | ● | ● | TNT825-CN | 无汞试剂消解法,需另配DRB200消解器 | ||
| 15-150 mg/L | ● | ● | ● | ● | 2038225-CN | 165℃ 20分钟快速消解法,需另配 DRB200消解器 | |
| 100-1000 mg/L | ● | ● | ● | ● | 2038325-CN | ||
| 高锰酸盐指数(CODMn) | 0.50 - 5.00 mg /L | ● | ● | ● | ● | 25156000-CN | 需另配DRB200消解器 |
| 溶解氧 | 10-1000μg/L O2 | ● | 2501025-CN | ||||
| 6-800μg/L O2 | ● | ● | ● | 2501025-CN | DR6000/DR3900/DR1900需另配10mL带盖样品池24276-06,比色计不需配 | ||
| 0.3-15.0mg/L O2 | ● | ● | ● | ● | 2515025-CN | ||
| 1.0-40.0mg/L O2 | ● | ● | ● | 2515025-CN | |||
| 除氧剂 | 5-600μg/L 碳酰肼 | ● | ● | ● | ● | 2446600-CN | 需另配25mL的样品池24019-06(DR900不需要) |
| 3-450μg/L DEHA | ● | ● | ● | ● | |||
| 9-1000μg/L 对苯二酚 | ● | ● | ● | ● | |||
| 13-1500μg/L 异抗坏血酸 | ● | ● | ● | ● | |||
| 15-1000μg/L 甲乙酮肟 | ● | ● | ● | ● | |||
| 臭氧 | 0.01-0.25mg/L O3 | ● | ● | ● | ● | 2516025-CN | |
| 0.01-0.75mg/L O3 | ● | ● | ● | ● | 2517025-CN | ||
| 0.01-1.50mg/L O3 | ● | ● | ● | ● | 25180-25 | ||
| 0.01-1.35 mg/L O3 | ● | ● | ● | ● | 2105669-CN | DPD法,详情可联系哈希 | |
| 土壤中多氯联苯(PCB) | 1-5mg/L; 10~50mg/L | ● | ● | ● | 27735-00+27752-00 | 免疫管法,另外需要多种配件,具体请参考方法手册。 | |
| 挥发酚 | 0.002-0.200mg/L | ● | ● | ● | 42449-CN | 需自行购买氯仿 | |
| 87299-CN | |||||||
| 183699-CN | |||||||
| 膦酸盐 | 紫外消解法(多个量程0.02-2.50或1.0-125.0) | ● | ● | ● | ● | 2429700-CN | 需另配25ml的带盖样品瓶(17042-00)紫外灯(20828-02)DR900系列无需配样品瓶 |
| 酸可水解磷 | 0.07-5.0 | ● | 2742745-CN | ||||
| 0.06-3.50 | ● | ● | ● | ||||
| 正磷酸盐(活性磷) | 0.23-30.00 | ● | ● | ● | ● | 2244100-CN | |
| 0.3-45.0 | ● | ● | ● | ● | 2076032-CN | ||
| 1.0-100.0 | ● | ● | ● | ● | 2767345-CN | ||
| 19-3000 ug/L | ● | ● | ● | 26786-00 | 需另配流通池,订货信息详见相关产品的 订购指南 | ||
| 0.06-5.00 | ● | ● | ● | ● | 2742545-CN | ||
| 0.02-2.50 | ● | ● | ● | ● | 2106069-CN | 高浊度/色度水样最好另外配预处理粉枕 试剂(14501-99) | |
| 5.0-90.0 | ● | ● | ● | TNT846-CN | 高浊度/色度水样最好另外配空白样品瓶 | ||
| 总磷 | 0.06-3.50 | ● | ● | ● | ● | 2742645-CN | 需要DRB200配备16mm的消解孔 |
| 1.0-100.0 | ● | ● | ● | ● | 2767245-CN | 需要DRB200配备16mm的消解孔 | |
| 活性磷&总磷 | 0.15-4.50 | ● | ● | ● | TNT843 | ||
| 1.5-15.0 | ● | ● | ● | TNT844 | |||
| 6-60 | ● | ● | ● | TNT845 | |||
| 钾 | 0.1-7.0 | ● | ● | ● | 2459100-CN | ||
| 季铵盐 | 0.2-5.0 CTAB | ● | ● | ● | 2459200-CN | 需另配:25mL的样品瓶(17042-00);由于该方法使用后的样品池容易形成一层粉色或紫色的物质,用哈希的Alconox清洗剂(20880-00)清洗更方便。 | |
| 硒 | 0.01-1.00 | ● | ● | ● | 22442-01 | 需另配25mL的带盖比色池26126-02. | |
| 硅 | 1.0-100.0 SiO2 | ● | ● | ● | ● | 2429600-CN | |
| 0.01-1.60 SiO2 | ● | ● | ● | ● | 2459300-CN | ||
| 3-1000 ug/L SiO2 | ● | ● | ● | 2553500-CN | 需配1英寸塑料比色池[2410222] | ||
| 银 | 0.005-0.700 | ● | ● | ● | 2296600-CN | 存在氰化物、硫代硫酸盐、有机物质等干扰因素时, 需要对样品进行消解。请配置哈希的Digesdahl消解 装置23130-21及安全挡板50040-00. | |
| 硫酸盐 | 5-70 | ● | 2106769-CN | ||||
| 2-70 | ● | ● | ● | ||||
| 40-150 | ● | ● | ● | TNT864-CN | |||
| 150-900 | ● | ● | ● | TNT865 | |||
| 硫化物 | 0.01-0.7 S | ● | |||||
| 5-800 ug/L S | ● | ● | ● | 2244500-CN | |||
| 亚硫酸盐 | 0.10-5.0 | ● | ● | ● | HPT430-CN | 试剂只适用于欧洲 | |
| 阴离子 表面活性剂(洗涤剂) | 0.002-0.275 LAS | ● | ● | ● | ● | 24468-01 | 必须配25mL的带盖比色池26126-02. |
| 悬浮固体 | 5-750 | ● | ● | ● | ● | - | |
| 单宁酸和木质素 | 0.1-9.0 | ● | ● | ● | ● | 2244600-CN | |
| 毒性 | 0-100% 抑制率 | ● | ● | ● | ● | 2597200-CN | 需另配培养器(22814-00) |
| 土壤中的总石油烃(TPH) | 免疫管法 | ● | ● | ● | 2774300-CN | 需另配土壤提取组件(27752-00). | |
| 水中的总石油烃(TPH) | 免疫管法 | ● | ● | ● | 2774300-CN | ||
| 三卤甲烷 | 10-600 μg/L CHCl3 | ● | ● | ● | 2790800 | 需另配20mmDRB200和消解管[LZP065] | |
| 挥发性酸 | 27-2800 CH3COOH | ● | ● | ● | ● | 2244700-CN | 需另配带盖样品池(24019-06). |
| 50-2500 CH3COOH | ● | ● | ● | TNT872-CN | |||
| 锌 | 0.01-3.00 | ● | ● | ● | ● | 2429300-CN | |
| 尿素 | 0-6 mg/L | ● | ● | ● | 二乙酰一肟分光光度法,需配DRB200和16mm消解管[2517600],试剂需自配,详情可联系哈希 | ||
| 水中油 | 0-4 mg/L | ● | 紫外法,萃取剂为正庚烷,需配置石英1cm比色皿[4822800],详情可联系哈希 | ||||
| 空气中氨 | 0.16-3.3 [mg/m3] | ● | ● | ● | 2458200-CN | 纳氏法,需自配采样器、吸附管,详情可联系哈希 | |
| 空气中氨 | 0.16-3.3 [mg/m3] | ● | ● | ● | 2604545-CN | 水杨酸法,需自配采样器、吸附管,详情可联系哈希 | |
| 空气中硫化氢 | 0.005-0.13 [mg/m3] | ● | ● | ● | 2244500-CN | 需自配采样器、吸附管,详情可联系哈希 | |
| 空气中氮氧化物 | 0.0024-2.0 [mg/m3] | ● | ● | ● | 需配16mm空管[2517600],自配采样器、吸附管,试剂需自配,详情可联系哈希 | ||
| 空气中甲醛 | 0.0075-0.4 [mg/m3] | ● | ● | ● | 2257700-CN | 需配DRB200和16mm空管[2517600],详情可联系哈希 | |